Share:


Experimental investigation of pull out strength of flexible ties in thin brick veneer layer

    Robertas Zavalis Affiliation
    ; Bronius Jonaitis Affiliation

Abstract

The use of thin brick veneer layers for building facades becomes more popular nowadays. Using thin bricks (50−65 mm thick) instead of normal 100−120 mm thick bricks let us to save expenses up to 50% related to materials. The connection of thin veneer layer with inner construction wall must be assured. Usually, the connection is fulfilled using flexible metal or composite ties. The main issue for this connection is tie pull out strength from thin brick masonry. This strength depends on type and construction of ties and it governs the number of ties need for facades. This article describes experimental research of pull out strength of flexible steel ties in thin brick masonry. Two possible anchoring types were used. Experimental test results and analysis are described in the article.


First published online 20 February 2020

Keyword : thin brick veneer layer, flexible steel ties, pull out strength

How to Cite
Zavalis, R., & Jonaitis, B. (2019). Experimental investigation of pull out strength of flexible ties in thin brick veneer layer. Engineering Structures and Technologies, 11(4), 114-118. https://doi.org/10.3846/est.2019.12055
Published in Issue
Dec 31, 2019
Abstract Views
2016
PDF Downloads
418
Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

References

Choi, Y. H., & LaFave, J. M. (2004). Performance of corrugated metal ties for brick veneer wall systems. Journal of Materials in Civil Engineering, 16(3), 202–211. https://doi.org/10.1061/(ASCE)0899-1561(2004)16:3(202)

Jonaitis, B., Zavalis, R., & Oganian, J. (2017). Experimental investigation of the behaviour of brick lintels. Procedia Engineering, 172, 465–472. https://doi.org/10.1016/j.proeng.2017.02.054

Lithuanian Standards Board. (2006). Eurocode 6. Design of masonry structures. General rules for reinforced and unreinforced masonry structures (LST EN 1996-1-1). http://lsd.lt/index.php?-767145819

Lithuanian Standards Board. (2007). Methods of test for mortar for masonary – Part 11: Determination of flexural and compressive strength of hardened mortar (LST EN 1015-11). http://lsd.lt/index.php?-1883030193

Lithuanian Standards Board. (2011). Methods of test for masonry units. Determination of water absorption of clay and calcium silicate masonry units by cold water absorption (LST EN 772-21). http://www.lsd.lt/index.php?-129382169

Lithuanian Standards Board. (2012). Methods of test for ancillary components for masonry. Determination of tensile and compressive load capacity and load displacement characteristics of wall ties (couplet test) (LST EN 846-5). http://lsd.lt/index.php?1867442866

Lithuanian Standards Board. (2014). Methods of test for masonry units. Determination of water absorption of aggregate concrete, autoclaved aerated concrete, manufactured stone and natural stone masonry units due to capillary action and the initial rate of water absorption of clay masonry units (LST EN 772-11). http://www.lsd.lt/index.php?-1877331342

Lithuanian Standards Board. (2017). Specification for mortar for masonry. Masonry mortar (LST EN 998-2). http://www.lsd.lt/index.php?878455058

Martins, A., Vasconcelos, G., & Costa, A. C. (2017a). Experimental assessment of the mechanical behaviour of ties on brick veneers anchored to brick masonry infills. Construction and Building Materials, 156, 515–531. https://doi.org/10.1016/j.conbuildmat.2017.09.013

Martins, A., Vasconcelos, G., & Costa, A. C. (2017b). Brick masonry veneer walls: an overview. Journal of Building Engineering, 9, 29–41. https://doi.org/10.1016/j.jobe.2016.11.005

Reneckis, D., & LaFave, J. M. (2012). Out-of-plane seismic performance and fragility analysis of anchored brick veneer. Structural Safety, 35, 1–17. https://doi.org/10.1016/j.strusafe.2011.10.003